Honeywell BW Flex 4/5 – 5-Gas Detector
The Honeywell BW Flex 4/5 is a portable multi-gas detector designed for industrial applications, environmental investigations and contaminated soil remediation. The detector supports up to four sensors and can monitor up to five gases simultaneously.
The device features a digital gas concentration display, audible, visual and vibration alarms, and Bluetooth connectivity. It is suitable for professional users familiar with portable gas detection equipment.
Detectable Gases – Custom Configuration
- LEL: Flammable gases and vapours, including methane (CH4) with a suitable sensor.
- O2: Oxygen deficiency and enrichment.
- H2S: Hydrogen sulphide.
- HCN: Hydrogen cyanide.
Five-gas monitoring is achieved using dual-sensor technology. The final sensor configuration, measurement channels and methane detection method must be confirmed when ordering. LEL monitoring and a separate CH4 concentration measurement are not equivalent.
Application Example: Contaminated Soil Remediation
During contaminated soil investigations and remediation projects, workers may be exposed to flammable or toxic gases released from the ground. Gas monitoring may be required during soil sampling, excavation, work near inspection chambers and other remediation activities.
The Honeywell BW Flex 4/5 enables simultaneous monitoring of multiple gas hazards with a single portable instrument. The display shows gas concentrations, while alarms warn the user when configured alarm thresholds are exceeded.
Gas sensors and alarm settings must be selected according to the site-specific risk assessment.
Bump Testing
A bump test verifies that the gas sensors respond to a known test gas and that the detector's alarm functions operate correctly.
- Bump testing requires an appropriate external test gas.
- Manual testing requires a compatible test gas cylinder, regulator, tubing and calibration cap.
- Automated testing is supported using a compatible Honeywell IntelliDoX testing and calibration station.
- Test gas concentrations and composition must match the installed sensors and manufacturer's instructions.
- Additional test gas may be required for the HCN sensor.
Honeywell recommends bump testing before each day of use. Testing must be performed according to the instrument user manual and applicable workplace safety procedures.
Calibration and Maintenance
- LEL sensor: Maximum calibration interval of 180 days.
- O2 sensor: Maximum calibration interval of 180 days.
- H2S sensor: Maximum calibration interval of 180 days.
- HCN sensor: Maximum calibration interval of 90 days.
Calibration intervals depend on the installed sensors, operating conditions and manufacturer requirements. More frequent calibration may be necessary.
The detector supports calibration reminders and automated calibration using Honeywell IntelliDoX. The integrated Reflex function automatically performs sensor diagnostics every 10 minutes. Internal diagnostics do not replace gas bump testing or calibration.
Compatibility and Accessories
- Test gases: Gas composition and concentrations must be suitable for the installed sensor configuration.
- Calibration cap: Use a compatible Honeywell BW Flex 4/5 calibration cap.
- Testing station: Compatible with the Honeywell IntelliDoX system.
- Wireless connectivity: Bluetooth Low Energy (BLE).
- Software: Honeywell Safety Suite, Device Configurator and Safety Communicator.
- Sensor maintenance: Modular construction supports servicing and sensor replacement.
Compatibility of existing gas cylinders, regulators, calibration caps and docking stations must be checked separately. Accessories from other manufacturers or different Honeywell detector models may not be compatible.
Technical Specifications
- Manufacturer: Honeywell
- Model: BW Flex 4/5
- Sensors: Up to 4 sensors, monitoring up to 5 gases
- Display: Simultaneous or individual gas concentration readings
- Alarms: Audible 95 dB, visual and vibration
- Alarm functions: Low, high, TWA and STEL
- Operation: One-button user interface
- Connectivity: Bluetooth Low Energy
- Ingress protection: IP66 / IP68
- Dimensions: 108.2 x 61.5 x 43.2 mm with alligator clip
- Weight: 186–189 g depending on sensor type
- Operating temperature: Sensor-dependent; verify the final configuration
- Approvals: ATEX, IECEx and other configuration-dependent certifications
Important Information Before Use
This detector requires a configuration suitable for the intended application. Before use, verify the installed sensors, calibration status, alarm settings and successful bump test result.
The Honeywell infrared LEL sensor cannot detect hydrogen or acetylene. A suitable catalytic LEL sensor must be selected for applications involving these gases.
According to Honeywell, some sensor combinations are not recommended or approved due to potential cross-sensitivities and interference. The final configuration and suitability for the intended application must be confirmed before ordering.