Chemical, Flame, Hivis | 18% Cotton







- Product Code: FR606


Portwest FR606 Multinorm Hi-Vis Winter Jacket with Chemical and Flame Protection
Keyword: Portwest FR606 Multinorm Hi-Vis Winter Jacket
Availability: Delivery time approx. 7 days from order.
Sizes: S–3XL
Return policy: 80% refund if returned in perfect condition, original packaging, and with all tags attached.
High-Performance FR Winter Jacket with Chemical, Antistatic, and Arc Protection
The Portwest FR606 Multinorm Hi-Vis Winter Jacket offers exceptional protection against flames, chemicals, and weather conditions. Designed for professionals working in demanding environments, this jacket combines flame resistance, waterproofing, chemical resistance, and antistatic protection in one modern design. Its extended back and ergonomic structure provide superior comfort and coverage during active work.
Key Features
- Inherent flame-resistant fabric properties that never wash out
- Protection against radiant, convective, and contact heat
- Fully lined and padded for insulation in cold conditions
- FR cotton lining for enhanced comfort and warmth
- Segmented heat-applied reflective tape increases flexibility and visibility
- Acti-Reach™ panel construction improves mobility and reduces friction
- 3 functional pockets for tools and devices
- Two zippered outer pockets for secure storage
- Internal tablet pocket for device protection
- Detachable and adjustable hood compatible with helmets
- Double storm flap for maximum weather protection
- Adjustable cuffs and inner knitted wrist for warmth and comfort
- Extended back design for lower back protection
- Radio loop for easy radio attachment
- Suitable for use in ATEX environments
- CE certified, CE CAT III classification
- Non-magnetic – contains no nickel or ferrous metals
Materials and Construction
- Outer fabric: Modaflame™ Rain Hi-Vis – 60% polyester, 21% modacrylic, 18% cotton, 1% carbon fibre, 7mm ripstop PU-coated, 270 g
- Lining: 100% cotton flame-resistant lining, 170 g
- Padding: 100% polyester flame-resistant wadding, 150 g
Standards and Certifications
- EN ISO 11612 A1+A2, B1, C1, F1 – Heat and flame protection
- EN ISO 11611 Class 1 A1+A2 – Welding protection
- EN 1149-5 – Antistatic properties
- IEC 61482-2 (Arc protection): IEC 61482-1-1 ELIM 32 cal/cm², ATPV 37 cal/cm²
- IEC 61482-1-2 APC 2 – Arc flash protection
- EN 13034 Type 6 – Chemical splash protection
- EN ISO 20471 Class 2 – High visibility
- RIS 3279 TOM Clause 2 (Orange only) – Rail industry standard
- EN 343 Class 4:1 X – Waterproof and breathable
- EN 342 0.337 (M²·K/W), 2, X – Cold protection
Washing Instructions
- Machine wash max 40°C, gentle cycle
- Do not bleach, tumble dry, or dry clean
- Hang dry only
- Do not iron reflective areas
Frequently Asked Questions (FAQ)
What protection levels does the FR606 jacket provide?
The jacket provides certified protection against heat, flame, chemicals, static, and electric arc flash, complying with multiple EN and IEC standards.
Is the jacket waterproof?
Yes, the FR606 is fully waterproof and breathable, certified to EN 343 Class 4:1 X, with a double storm flap and PU-coated ripstop fabric.
Can the hood be used with a safety helmet?
Yes, the detachable hood is helmet-compatible and adjustable for a secure fit, with a shaped peak for added weather protection.
Is this jacket suitable for ATEX environments?
Yes, the non-magnetic, antistatic fabric and construction make it suitable for ATEX and other explosive-risk areas.
Does the jacket offer arc flash protection?
Yes, it provides high-level arc flash protection with an ELIM rating of 32 cal/cm² and ATPV rating of 37 cal/cm².
Washing Instructions
- Maximum wash temperature 40°C, gentle cycle
- Do not bleach
- Do not tumble dry
- Hang dry or use a drying rack
- Do not iron
- Do not dry clean
Standards and Certifications
| Standard | Official English Name | Finnish Description |
|---|---|---|
| EN ISO 11612 A1+A2, B1, C1, F1 | Protective clothing – Clothing to protect against heat and flame | Suojaa käyttäjää kuumuudelta ja liekeiltä |
| EN ISO 11611 Class 1 A1+A2 | Protective clothing for use in welding and allied processes | Hitsaukseen ja vastaaviin töihin tarkoitettu suojavaatetus |
| EN 1149-5 | Protective clothing – Electrostatic properties | Antistaattinen suojaus, estää staattisen sähkön purkauksia |
| IEC 61482-2 | Protective clothing against the thermal hazards of an electric arc | Valokaarisuojattu vaatetus (ARC-suojaus) |
| IEC 61482-1-1 | Open arc test method (ELIM / ATPV values) | Avoimen valokaaren testimenetelmä (energialuokitus cal/cm²) |
| IEC 61482-1-2 | Box test method (APC levels) | Kotelotestimenetelmä valokaarisuojauksen tasoille |
| EN 13034 Type 6 | Protective clothing against liquid chemicals – Type 6 | Rajoitettu suojaus nestemäisiä kemikaaliroiskeita vastaan |
| EN ISO 20471 Class 2 | High-visibility clothing – Test methods and requirements | Näkyvyyttä lisäävä suojavaatetus (luokka 2) |
| RIS 3279 TOM Clause 2 (Orange only) | Rail Industry Standard for High-Visibility Clothing (UK rail) | Rautatiealan oranssin huomiovärin vaatimus (vain oranssi) |
| EN 343 Class 4:1 X | Protective clothing – Protection against rain | Vedenpitävyys ja hengittävyysluokitus |
| EN 342 0.337 (M²·K/W), 2, X | Protective clothing – Protection against cold | Kylmäsuojaus ja lämmöneristävyys |
